AN1913 SEE ISL70003SEH

General data

The part was tested for SEL/SEB/SEGR, using Au ions at zero degree incidence (LET = 86.4MeV•cm2/mg) SEFI tests conducted with Au ions were done with the samples at zero degree incident beam angle and tests with Pr ions were done with a 15° incident beam angle to achieve an LET of 60MeV•cm2/mg. SET testing of the ISL70003SEH was carried out with the samples configured as a single-phase converter operating at 3.0A output current. The samples were irradiated using Au ions at a zero degree incident beam angle for an effective LET of 86MeV•cm2/mg.